Product Specification
|
Principle |
Visual Immunochromatography |
|
Storage |
4-30°C |
|
Shelf Life |
36 Months |
|
Reading Time |
10-20 Minutes |
|
Relative Sensitivity COVID-19 |
97.87% |
|
Relative Specificity COVID-19 |
100% |
|
Overall Agreement COVID-19 |
99.12% |
|
|
Influenza A | Influenza B |
|
Relative Sensitivity |
100% | 97.22% |
|
Relative Specificity |
99.44% | 99.36% |
|
Overall Agreement |
99.58% | 98.96% |
Product Advantages
- 3 in 1 Respiratory Infection Screening
- High Clinical Performance
- Reliable Specificity with Minimal Cross-Reactivity
- OEM & Private Label Available
Custom Logo Printing
Customized Color Boxes
Multilingual Instructions
Private Label Branding
Bulk Manufacturing Supply
Ordering Information
|
Catalog No. |
Product Name |
Specimen |
Format |
Pack |
Certification |
|
FCO-6032a |
Multi-Respiratory Virus Antigen Test Kit(Swab)(Influenza A+B/ COVID-19) |
nasal swabs nasopharyngeal swabs oropharyngeal swabs |
Cassette |
1Test /Kit 2Tests /Kit 5Tests /Kit 10Tests /Kit 20Tests /Kit 25Tests /Kit |
CE |
[Specimen Collection]
- Inadequate specimen collection or improper specimen handling may yield a false result.
- Prior to collecting the nasopharyngeal swab, the patient should be instructed toblow their nose.
- Nasal Swabbing:
1) Insert the swab into one nostril of the patient. The swab tip should be inserted up to 2.5 cm (1 inch)
from the edge of the nostril. Roll the swab 5 times along the mucosa inside the nostril to ensure that
both mucus and cells are collected.
2) Using the same swab, repeat this process for the other nostril to ensure that an adequate sample is
collected from both nasal cavities.
3) Withdraw the swab from the nasal cavity.

- Nasopharyngeal Swabbing:
1) Tilt the patient's head back. Insert the swab through the nostril that presents the most secretion
under visual inspection.
2) Keep the swab near the septum floor of the nose while gently pushing the swab into the posterior
nasopharynx. Rotate the swab several times.
3) Leave the swab in place for several seconds then remove it from the nasopharynx.

- Oropharyngeal swabbing:
Open mouth wide. Insert the sterile swab into throat. Rub the soft tip of the swab over both columns of the tonsils and the posterior oropharynx, avoiding touching the tongue, teeth, and gums.

[Specimen Preparation]
1. Peel off the foil film on the extraction tube and insert into the hole of workstation.For 1 test/kit and 5 tests/kit, Insert the extraction tube into the hole of the box.)
2. Insert the swab into the extraction tube which contains buffer. Rotate the swab at least 8-10times while pressing the swab against the bottom and side of the extraction tube.
3. Remove the nasal swab while squeezing and rolling the nasal swab against the sides of the tube to release as much liquid as possible
4. Cover the tube with cap tightly and insert the tube back into the workstation or box.

ASSAY PROCEDURE
Allow the test device and specimens to equilibrate to room temperature(15-30℃ or 59-86℉) prior to testing. For best results, the test should be performed in one hour.
1. Remove the test device from the sealed pouch.
2. Reverse the specimen extraction tube, holding the specimen extraction tube upright, transfer 3 drops to each specimen well(S) of the test device, then start the timer.
3.Wait for colored lines to appear. Interpret the test results at 10-15 minutes. Do not read results after 20 minutes.

FAQ
Q: What types of samples can be tested?
A: The test can be performed using nasal swabs nasopharyngeal swabs or oropharyngeal swabs
.
Hot Tags: Multi-Respiratory Virus Antigen Test Kit(Swab) (Influenza A+B/ COVID-19), China Multi-Respiratory Virus Antigen Test Kit(Swab) (Influenza A+B/ COVID-19) manufacturers, suppliers, factory, COVID 19 Antigen Rapid Test Kit Swab For Selftesting, COVID 19 FLU RSV ADVAntigen Combo Rapid Test Swab , COVID 19 Flu RSV Antigen Combo Rapid Test Swab , COVID 19 Influenza A B Antigen Combo Rapid Test For Self Testing, COVID IgG IgM Test Device, COVID IgM Test Device